| VOC Gas transmitter |
¡¡ |
|
| RAE
Guard |
|
°íÁ¤Çü PID transmitter |
|
|
|
Ãâ·Â |
4-20 mA |
|
|
µðÅØÅÍ |
3D
PID sensor, 10,6eV
Lamp |
|
|
ÀÔ·ÂÀü¾Ð: |
9-36VDC |
|
|
ÃøÁ¤¹üÀ§ |
0.1 to 99.9 ppm : 1 to 999 ppm |
|
|
0.01 to 9.99 ppm isobutylene
equivalent ÀÇ ¼¼¹öÀüÁß ÅÃÀÏ |
|
|
¹æÆøÇü,³»ÀåÆßÇÁÇü |
|
|
¿ë µµ |
¼öó¸®,¿ÀÀÏ,Á¤À¯,¹ßÀü¼Ò, |
|
|
Á¦Áö°øÀå,µµÀå°øÁ¤,°ø±âÁ¤È |
|
|
¹ÝÀÀ½Ã°£ |
20ÃÊ to 90% reading of Isobutane |
|
|
| CO2
°¡½º Æ®·£½º¹ÌÅÍ
Airsense ( USA) |
|
|
|
|
http://www.korins.com/m/dcs |
|
| ³ó»ç¹°
º¸°üâ°í,¹ö¼¸³óÀå,°Ç¹°È¯°æ°ü¸®,ÀÚµ¿Á¦¾î |
|
| NDIR¹æ½ÄÀ¸·Î ¼Ò¸ðǰ
±³Ã¼ ¾øÀÌ ¹Ý¿µ±¸Àû »ç¿ë°¡´É |
|
| ÃøÁ¤¹üÀ§ ¹× Ãâ·ÂÁ¾·ù
»ç¿ëÀÚ ¼±ÅÃÁ¶Á¤ °¡´É |
|
|
Model |
AIRSENSE 310 |
¡¡ |
¡¡ |
|
|
¡¡ |
|
| ¡¡ |
|
ÀÛµ¿¿ø¸® |
NDIR ¹æ½Ä |
¡¡ |
¡¡ |
|
| ¡¡ |
|
ÃøÁ¤¹üÀ§ |
0~1000/0~5000(ppm) |
¡¡ |
|
| ¡¡ |
|
Ãâ·Â |
4~20mA / 0~10(volts) |
¡¡ |
|
| ¡¡ |
|
Á¤¹Ðµµ |
5% of m.v |
¡¡ |
¡¡ |
|
| ¡¡ |
|
ÀçÇö¼º |
20ppm |
¡¡ |
¡¡ |
|
| ¡¡ |
|
¹ÝÀÀ½Ã°£ |
60ÃÊ ÀÌÇÏ |
¡¡ |
¡¡ |
|
| ¡¡ |
|
ÀÛµ¿¿Âµµ |
0~50(`C) |
¡¡ |
¡¡ |
|
| ¡¡ |
|
ÀÛµ¿½Àµµ |
0~90(%RH) |
¡¡ |
¡¡ |
|
| ¡¡ |
|
ÀÔ·ÂÀü¾Ð |
18~30(VDC) |
|
| ¡¡ |
¡¡ |
¡¡ |
|
|
| Àû¿Ü¼±°¡½ºÃøÁ¤±â |
¡¡ |
¡¡ |
ADC(¿µ±¹) |
¡¡ |
¡¡ |
|
| MGA3000 Multi-Gas Analzser |
|
http://www.korins.com/m/adc |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MGA3000 |
|
Eclipse |
|
| GAS |
SYMBOL |
GC Á¦Ç° |
SB Á¦Ç° |
|
| Carbon Dioxide |
CO2 |
50ppm |
0.10% |
|
| Carbon Monoxide |
CO |
100ppm |
2.00% |
|
| Sulphur
Dioxide |
SO2 |
500ppm |
1.00% |
|
| Sulphur
Hexafluoride |
SF6 |
¡¡ |
0.20% |
|
| Nitroic
Oxide |
NO |
500ppm |
¡¡ |
|
| Nitrous
Oxide |
N2O |
300ppm |
0.10% |
|
| Ammonia |
NH3 |
¡¡ |
2.00% |
|
| Methane |
CH4 |
300ppm |
2.00% |
|
| Ethane |
C2H6 |
500ppm |
1.00% |
|
| Prophane |
C3H8 |
¡¡ |
1.00% |
|
| Butane |
C4H10 |
¡¡ |
0.50% |
|
| Pentane |
C5H12 |
¡¡ |
0.50% |
|
| Hexane |
C6H14 |
¡¡ |
0.50% |
|
| Benzene |
C6H6 |
5000ppm |
1.00% |
|
| Toluene |
C6H5CH3 |
¡¡ |
1.00% |
|
| Hydrogen
Chloride |
HCL |
500ppm |
¡¡ |
|
| Dichloromethane |
CH2CL2 |
¡¡ |
2.00% |
|
|
| ION
SCIENCE °¡½º ÃøÁ¤±â |
¡¡ |
http://www.ionscience.co.kr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GAS CHECK 3000/5000 |
|
PhoCheck |
Gas Check SF6 |
|
| Helium Hydrogen, Argon |
³Ã¸Å¿ë( Gas Check R2Pc) |
VOC (PID ½ë¼) |
SF6 ÃøÁ¤±â |
|
| ¡¡ |
Gas Check3000/5000 |
PhoCheck |
Gas Check R2Pc |
Gas Check DF6 |
|
| Detector |
Micro volume thermal
conductivity cell |
2000/3000/4000 |
Microprocessor controlled
ceramic sensor with extremely low cross-sensitivity to interfering gases such
as alcohol. |
Negative Ion Capture (NIC)
operating in partial vacuum |
|
| Sensitivity
(cc/sec) |
He 1x10-5 CH4 1x10-4 R12 8x10-5 Ar 1x10-4 |
¡¡ |
1.3 x 10-6 |
1x10-7 cc/sec, 1 ppm, 0.2 gm/yr |
|
| Response |
1 second with 1 second clear
down time |
1ppb RANGE: 0-10000 ppm |
1 second with 10 second clear
down time |
<1 sec. Cleardown also <1
sec |
|
| ÃøÁ¤ ¿ëµµ |
Helium
,Hydrogen, Argon |
VOC |
³Ã¸Å¿ë |
SF6 |
|
|
|
|
|
|
|
|
|
|